FRI-OS Cu/FR/OS/LSZH

Chi tiết - FRI-OS Cu/FR/OS/LSZH

Home page/solutions/FRI-OS Cu/FR/OS/LSZH

FRI-OS Cu/FR/OS/LSZH

ESCAB fire resistant instrumentation cables, these cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor applications. These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply. Recommended for use where circuit integrity is required in case of fire.

1 - Conductor : Stranded electrolytic copper conductor (Class 2) (IEC/EN 60228)
2 - Insulation : Fire resistant layer
3 - Stranding : In layers
4 - Wrapping : Polyester tape fire resistant layer
5 - Screen : Al/PET tape & drain wire.
6 - Outer Jacket : UV resistant halogen-free outer jacket.

Part Number Ref:EF63S-010210

Description

ESCAB FRI-OS Cu/FR/OS/LSZH  300/500V

Order information:

P/N Ref Size
(m2)
EF63S-010208 ESCAB FRI-OS CU/FR/OS/LSHF  1 x 2 x 0.75     600/1000V
EF63S-010210 ESCAB FRI-OS CU/FR/OS/LSHF  1 x 2 x 1.00    600/1000V
EF63S-010215 ESCAB FRI-OS CU/FR/OS/LSHF  1 x 2 x 1.50    600/1000V
EF63S-010225 ESCAB FRI-OS CU/FR/OS/LSHF  1 x 2 x 2.50    600/1000V
EF63S-020208 ESCAB FRI-OS CU/FR/OS/LSHF  2 x 2 x 0.75     600/1000V
EF63S-020210 ESCAB FRI-OS CU/FR/OS/LSHF  2 x 2 x 1.00    600/1000V
EF63S-020215 ESCAB FRI-OS CU/FR/OS/LSHF  2 x 2 x 1.50    600/1000V
EF63S-020225 ESCAB FRI-OS CU/FR/OS/LSHF  2 x 2 x 2.50    600/1000V
EF63S-030208 ESCAB FRI-OS CU/FR/OS/LSHF  3 x 2 x 0.75     600/1000V
EF63S-030210 ESCAB FRI-OS CU/FR/OS/LSHF  3 x 2 x 1.00    600/1000V
EF63S-030215 ESCAB FRI-OS CU/FR/OS/LSHF  3 x 2 x 1.50    600/1000V
EF63S-030225 ESCAB FRI-OS CU/FR/OS/LSHF  3 x 2 x 2.50    600/1000V
EF63S-040208 ESCAB FRI-OS CU/FR/OS/LSHF  4 x 2 x 0.75     600/1000V
EF63S-040210 ESCAB FRI-OS CU/FR/OS/LSHF  4 x 2 x 1.00    600/1000V
EF63S-040215 ESCAB FRI-OS CU/FR/OS/LSHF  4 x 2 x 1.50    600/1000V
EF63S-040225 ESCAB FRI-OS CU/FR/OS/LSHF  4 x 2 x 2.50    600/1000V

 

Technical Document

Technical Specification

Standard:

Flame Tests: IEC/EN 60332-1-2, IEC 60332-3-24.
Smoke Density:  IEC/EN 61034
Corrosive Gas Measurement: IEC 60754-2, EN 50267
Fire test:  IEC 60331-21, (BS 6387CATCWZ option)

Operating Voltage: 300/500V  ; 600/1000V
Test Voltage: Core/Core 2000 V
Conductor Resistance (max.):
Temperature Range:  -30C … + 90C  Fixed  ;  -10C … + 90C Flexible
Minimum Bending Radius: 7.5 x Cable Diameter Fixed ;  10 x Cable Diameter Flexible

Price Quote